Medical Application: Non-Magnetic Connectors

CHIN NAN offers a wide range of non-magnetic coaxial connectors, including the SMA, SMA 27G, MCX, MMCX, SMB, and SMT series.

These non-magnetic coaxial connectors are specifically designed to meet the demands of MRI (Magnetic Resonance Imaging) medical equipment, where the absence of magnetic interference is crucial.

The production process involves meticulous selection of materials and plating, along with strictly controlled manufacturing and inspection procedures. This ensures that the quality and performance of the non-magnetic coaxial connectors meet the stringent requirements of medical applications.

 

Table of Content

 

 

Why Do I Need Non-Magnetic RF Coaxial Connectors?

Magnetic Resonance Imaging (MRI), originally known as Nuclear Magnetic Resonance (NMR), is a non-invasive imaging technology that uses powerful magnetic fields and radiofrequency waves combined with computer technology to generate cross-sectional images of the human body. MRI enables clinicians to effectively examine and diagnose internal structures and abnormalities in the body without exposing patients to radiation.

Modern medical diagnostics heavily rely on MRI equipment. In certain cases, components made with magnetic materials may interfere with the stability of the magnetic field, thereby affecting image quality. Poor-quality images can lead to diagnostic errors and even inappropriate treatments.

 

MRI-Equipment
MRI Equipment

 

The uniformity of the magnetic field and the signal-to-noise ratio are critical factors that affect the image quality of MRI. Therefore, selecting non-magnetic metals as materials is essential for the performance of MRI equipment.

Any magnetic components or materials can disrupt the uniformity of the magnetic field, thereby reducing imaging quality. To ensure imaging accuracy, coaxial connectors, cables, and capacitors used in MRI equipment should avoid the use of magnetic materials.

 

MRI-EquipmentMRI Equipment

 
MRI scan image of the brain
MRI scan image of the brain

 

With the continuous advancement of MRI technology, CHIN NAN has been consistently improving its low magnetic susceptibility non-magnetic connectors to meet the needs of the medical industry. Beyond the medical field, we have also discovered that non-magnetic plating technology is suitable for other industries requiring non-magnetic characteristics, such as WiFi communications, antennas, and measurement equipment.

 

Not sure if you need non-magnetic connectors? Contact our customer service team at service@chinnan.com.tw or fill out the contact form on our website, and let CHIN NAN provide you with expert advice!

 

 

 

How Does CHIN NAN Manufacture Non-Magnetic Coaxial Connectors?

Unlike standard coaxial connectors commonly made from brass or nickel materials in the market, non-magnetic coaxial connectors are typically produced using low magnetic susceptibility metals, such as alloys like beryllium copper, silver, or white bronze. Stainless steel, brass, or nickel containing trace amounts of iron may exhibit magnetic properties, making them less ideal materials for non-magnetic coaxial connectors.
 

CHIN NAN utilizes beryllium copper and high-quality non-magnetic plating to manufacture non-magnetic coaxial connectors. This eliminates magnetic interference while meeting the stringent manufacturing requirements of MRI systems and the medical industry.
 
By adhering to rigorous quality control procedures, CHIN NAN manufactures non-magnetic coaxial connectors through tightly controlled production and inspection processes. The machining and assembly are carried out in a clean environment to prevent any potential magnetic contamination, ensuring the superior magnetic properties of the non-magnetic connectors.


 

 

Testing Method

 

SQUID-VSM

Hysteresis loop & B-H curve of Magnetic Testing by SQUID
(Superconducting Quantum Interference Device)

 

  • Use SQUID VSM equipment to analyze and calculate the magnetic induction strength of each material under high magnetic field.
  • Calculate the total weight of materials in the product.
  • Combine various material parameters for calculation.
  • Confirm the total magnetic amount of the product meets customer quality requirements.
  • Perform magnetic quality inspection and confirmation of mass-produced products (using ultra-high magnetic strength magnets to test connectors).

 

Magnetic susceptibility

Magnetic susceptibility: quantitative measure of the extent
which a material may be magnetized in relation to a given applied magnetic field.
(Source: Encyclopedia Britannica)

 

 

Testing the connectors with 7000GS magnet(have space)

Non-magnetic connector is not attracted by magnet


Testing the connectors with 7000GS magnet(no space)

Standard connector is attracted by magnet

 

 

Features of Non-Magnetic RF Connectors

CHIN NAN's non-magnetic coaxial connectors have a low magnetic susceptibility, which minimizes magnetic field distortion and ensures superior image quality—traits essential for MRI or medical imaging equipment. Additionally, they offer excellent electrical and mechanical performance.

 

SMA Series

SMA Series Features

  • 0 GHz up to 18 GHz
  • 50 Ohm Impedance
  • Beryllium brass material for non-magnetic connectors
  • Ideal for medical applications like MRI
  • Conform to MIL-STD-348A standard interface
  • Outstanding mechanical durability
  • Non-magnetic options available for medical and aerospace applications

 

Want to learn more about our products? Explore CHIN NAN's high-performance SMA connectors specially selected for medical equipment to enhance signal transmission stability!

 

MCX Series

MCX Series Features

  • 0 GHz to 6 GHz
  • 50 Ω or 75 Ω options available 
  • Fast and easy snap-on / snap-off coupling
  • Conform to European CECC 22220 interface
  • 30% smaller than SMB
  • MMCX is smaller, has same foot print of MCX and has all features that MCX series has
  • Non-magnetic options available for medical and aerospace applications, including printed circuit board and cable connectors

 

Want to learn more about our products? Explore CHIN NAN's high-performance MCX connectors specially selected for medical equipment to enhance signal transmission stability!

 

 
 

Summary

CHIN NAN provides high-performance non-magnetic connectors that help improve scan quality and the readability and accuracy of images. We also offer a wide range of non-magnetic coaxial connector series for medical, communication, and measurement equipment, including SMA, SMA 27G, MCX, MMCX, SMB, and SMT. If there are special functional requirements, we can customize other series of connectors into non-magnetic connectors based on customer needs.
 

CHIN NAN has established a strictly controlled production and inspection process and a clean working environment to prevent any magnetic substances from affecting or interfering with the non-magnetic connectors during manufacturing. Our high-performance non-magnetic coaxial connectors provide better choices for manufacturers of MRI, other types of diagnostic imaging equipment, and any devices requiring non-magnetic interference.

 

If you are looking for more details about our non-magnetic connectors, click here to explore CHIN NAN's non-magnetic connector series.

Need further assistance? Contact our professional customer service team at service@chinnan.com.tw or fill out the contact form on our website, and let CHIN NAN provide you with expert advice on non-magnetic connectors!

Sign In / Register

Write a review

已送出
Thank you for your review
OK

We will use cookies on our website for technical, analytical, and marketing purposes. By continuing to browse this website, you agree to our use of cookies. To learn more, read our Privacy Policy. 

I AGREE

PRIVACY POLICY

LEGAL, TERMS & CONDITIONS

Chin Nan respects the privacy rights and interests of each customer. Chin Nan will observe the principles when processing your personal information fairly and lawfully. We take the protection of personal data very seriously. We want you to know when we are storing your data, what data we are storing and how we are using it.

PERSONAL INFORMATION YOU PROVIDE TO US THROUGH OUR SITE.

We may collect and store personal information that you choose to voluntarily provide to us when you provide it through the Site. The types of personal information may include:

  • Company name, contact name, job title, company website, country, business type, email,telephone number, fax number, address.

  • Other personal information you may include in content you submit on the Site.

COOKIE:

There is a technology called "cookie" which is an element of data that a website can send to your browser which may then store on your system. Some Site pages use cookies so that we can better serve you when you return to our Site. You can set your browser to notify you when you receive a cookie, giving the chance to decide whether to accept it.

We use Track ID (cookies) to collect and store information when you visit our website; the information is saved at Amazon Web Services (AWS) and used to identify your browser or device.

Cookies do not harm your computer and do not contain any viruses.

Cookies help make our website more user-friendly, efficient, and secure.

Cookies are small text files that are stored on your computer and saved by your browser. Using cookies enables us to provide you with certain features and provides us with information regarding website visits.

WEB ANALYSIS WITH GOOGLE ANALYTICS

We use Google Analytics to analyze user activity in order to improve the Website. For example, using Google Analytics Cookies we can look at aggregate patterns like the average number of searches that users perform, what keywords users searched, countries and languages. We can use such analysis to gain insights about how to improve the functionality and experience of the website. You can visit Google Analytics’ Privacy Policy at: https://policies.google.com/technologies/cookies

YOUR INFORMATION COLLECTED FROM OTHER TECHNOLOGIES

Besides Cookies, we use other technologies to improve your user experience and the overall quality of our services by collecting the information below:

[site visitor] visited website (URL)

[site visitor] IP Address

[site visitor] Internet Connection Device Brand, Model and OS

[site visitor] Internet Connection Device Browser, Resolution, Color

[site visitor] GeoIP

[site visitor] ISP

INFORMATION, BLOCKING, DELETION

As permitted by law, you have the right to be provided at any time with information free of charge about any of your personal data that is stored as well as its origin, the recipient and the purpose for which it has been processed. You also have the right to have this data corrected, blocked or deleted. You can contact us at any time using the address given in our legal notice if you have further questions on the topic of personal data.

All the collected information is saved for 24 months on Amazon Web Services (AWS) and regularly deleted every month..

THE PROTECTION OF YOUR PERSONAL DATA

Your personal data is stored on Amazon Web Services (AWS). AWS Announces CISPE Membership and Compliance with First-Ever Code of Conduct for Data Protection in the Cloud.

INFORMATION SECURITY

We use standard security technology SSL or HTTPS standard technology for keeping an internet connection secure and safeguarding any sensitive data that is being sent between two systems, preventing criminals from reading and modifying any information transferred, including potential personal details.

CHANGES TO THIS PRIVACY POLICY

We may update this Privacy Policy to reflect changes to our information practices. If we make any material changes we will notify you by email (sent to the e-mail address specified in your account) or by means of a notice on this website prior to the change becoming effective.